電線の太さの選択
電圧降下の計算式(簡易)
単相2線式
三相3線式(許容電圧降下率3%、降下電圧6V)
電線の選択(単位:mm2)
モーター出力 | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 19 | 22 | 37 | ||
電線(キャブタイヤ・ ケーブル)の 長さ(m) | 10 | 0.75 | 1.25 | 2.0 | 3.5 | 5.5 | 8.0 | 14.0 | 22.0 | 30.0 | 38.0 | 60.0 |
20 | 0.75 | 1.25 | 2.0 | 3.5 | 5.5 | 8.0 | 14.0 | 22.0 | 30.0 | 38.0 | 60.0 | |
30 | 0.75 | 1.25 | 2.0 | 3.5 | 5.5 | 8.0 | 14.0 | 22.0 | 30.0 | 38.0 | 60.0 | |
40 | 0.75 | 2.0 | 3.5 | 3.5 | 5.5 | 8.0 | 14.0 | 22.0 | 30.0 | 38.0 | 60.0 | |
50 | 1.25 | 2.0 | 3.5 | 5.5 | 8.0 | 14.0 | 22.0 | 22.0 | 30.0 | 38.0 | 60.0 | |
60 | 1.25 | 3.5 | 3.5 | 5.5 | 8.0 | 14.0 | 22.0 | 22.0 | 30.0 | 38.0 | 60.0 | |
70 | 2.0 | 3.5 | 5.5 | 8.0 | 14.0 | 14.0 | 22.0 | 30.0 | 30.0 | 38.0 | 60.0 | |
80 | 2.0 | 3.5 | 5.5 | 8.0 | 14.0 | 14.0 | 30.0 | 30.0 | 38.0 | 50.0 | 80.0 | |
90 | 2.0 | 3.5 | 5.5 | 8.0 | 14.0 | 22.0 | 30.0 | 38.0 | 50.0 | 50.0 | 80.0 | |
100 | 2.0 | 5.5 | 5.5 | 14.0 | 14.0 | 22.0 | 30.0 | 38.0 | 50.0 | 60.0 | 100.0 | |
110 | 2.0 | 5.5 | 8.0 | 14.0 | 22.0 | 22.0 | 38.0 | 38.0 | 50.0 | 60.0 | 100.0 | |
120 | 3.5 | 5.5 | 8.0 | 14.0 | 22.0 | 22.0 | 38.0 | 38.0 | 60.0 | 80.0 | 125.0 | |
130 | 3.5 | 5.5 | 8.0 | 14.0 | 22.0 | 30.0 | 50.0 | 50.0 | 60.0 | 80.0 | 125.0 |